Geotec and Geotab version 8.11.5

Geotec 8.11.5

Geotec has been updated with several improvements, modifications and fixes including the following. See the release history.

  • Laboratory tests
    • Limits entry form: Modification of the Swedish cone test to allow to enter up to 4 penetration values, and addition of an initial reading to be subtracted from values, if applicable.
    • Modification of field type from 7.3 to 11.3 for masses in Grain Size and Proctor (mould) to allow masses greater than 10,000 grams
    • Hydrometer entry form: Added times of 30 seconds and 1 minute
    • Hydrometer entry form: Addition of F correction factor for density
    • Grain Size entry form: Better management when changing sieving method
    • Proctor entry form: Can indicate a passing % at a certain diameter if the grain size test was not done
  • Rock mechanics:
    • Modification of the Joints and Runs entry forms and addition of calculations
    • Modification of the Point Load entry form and addition of calculations
    • Addition of UCT entry form (uniaxial compression test) and of calculations
    • Addition of Rock entry form (ROCK table) for default parameters in rock mechanics
    • Addition of ROCK_SET table to define default joint sets
    • New predefined curve for table ROCK_JOINT to display the number of joint or the average joint spacing per meter or per fraction of meter based on data entered
  • Google Maps
    • Improvements when adding axes and limits interactively with the mouse
    • Addition of axis creating without prior query
    • When creating an axis, conversion from longitude/latitude to geodesic coordinates based on coordinate systems of the selected site
    • Optimized display of the map and geotechnical entities based on coordinate systems
  • Soil matrix: Added “saturated” checkbox for moisture
  • Piezometers
    • Support of Leveloggers including calculations and graphic representation
    • Addition of barometric correction via the BAROMETER table for vibrating chord piezometers and Leveloggers
  • Piezocone tests: Addition of CONDUCTIVITY field and calculation between electrical conductivity (mS/m) and resistivity (ohm-m) based on resistivity = 1000 / conductivity
  • Entry forms: General
    • New buttons to toggle between Tabs, Datasheet and Columnar formats
    • New general calculation window opened by calculation functions
    • Calculations without the need to display data graphically (piezocone, grain size analysis, etc.)
    • Support of % for queries on dates in SQL Server and Oracle (ex: 2022-04%)
    • New batch calculation of sensitivity Su / Sur in Swedish Cone and Vane entry forms
    • Saving sample depths and lengths with 4 decimals instead of 3 to avoid rounding inaccuracies following feet – meter conversions
  • Graphic outputs: Corrected use of top depth in Log
  • Import External Data: Ability to edit the values in the Import Data window before inserting them in the database, and to resave the .csv file if desired
  • DBM
    • Addition of default records when creating and updating databases (sieving methods, hydrometer calibrations and grain size specifications)
    • Addition of warning messages in the update and transfer tasks
    • Correction in transfer loops when tables are unchecked
    • Modification of the default N4_VERTICAL view to show only N1, N2, N3, N4 and the remark one below the other
  • SKM
    • Correction to the uses available with the admin password (Geotab tab)
    • More explicit information on the licence or maintenance expiration of Geotec network licences

 

Geotab 8.11.5

The Geotab application on Android was updated with the following improvements. See the release history.

  • Mandatory selection of licence deactivation date
  • Correction to the automatic creation of layers: reset the list of debris
  • Correction to the automatic numbering of samples if the prefix has 1 character only
  • New parameter to set moisture before density / consistency in the descriptions
  • New Table format to view the entry forms (option “View as table”)
  • Automatic update of databases:
    • Modification of field R1 for READING in PIEZOMETRIC_LEVEL
    • Correction of field DATE_INSTALLATION for INSTALLATION_DATE in PIEZOMETER